Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Containerized Mobile Incinerator

 

Containerized Mobile Incinerator͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌   ͏ ‌  

Hospital Syringe and Destroyer-Needle Destroyer-Needle Incinerators

1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
Model SYC19, Price: $110usd/set, MOQ: 5 sets.
EXW factory term(donot including shipping cost)
Purchase email:  info@hiclover.com
Qustion1: If request 1-4 set only, how to do?
Answer: We will plus $50-$200usd fee per order.
Qustion2: If request more than 5 sets only, any discount?
Answer: We will  supply discount quotation accordingly.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

treatment of clinical waste using the incinerator

How medical waste is incinerated?
The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through 
an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases.


 

What are the treatment methods for treatment of bio medical waste?
Thermal processes
    Low-heat systems (operates between 93 -177oC) use steam, hot water, or electromagnetic radiation to heat and decontaminate the waste
    High-heat systems employ combustion and high temperature plasma to decontaminate and destroy the waste. …
    Incineration.
    Autoclaving.
    Microwaving.
    Deep Burial.

 
Nanjing Clover Medical Technology Co.,Ltd.
waste to energy plant suppliers
medical waste incinerator types
hospital waste disposal methods
ovens incineration sale
medical waste incinerators in south africa
where and how incinerator install

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

 

All incinerators shall meet the following emission and operating standards:
• Combustion efficiency (C.E.) shall be at least 99.0%
• The combustion efficiency shall be computed as follows:
o C.E = (CO2 X 100) / (%CO2 +%CO)
Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, 
shall be installed/retrofitted with the incinerator to achieve emission limits.”
“Each unit shall include a complete vertical exhaust and stack system, including the following features:
• Steel construction.
• Refractory lining in the lower section.
• The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending 
on the capacity of the incinerator unit. 
• The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not 
less than 10 metres per second vertically upwards when at full scale operation.
• An emission stack sampling port shall be included immediately above the secondary chamber.

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     sales@hiclover.com       
Email:    hicloversales@gmail.com    

HICLOVER Top Feeding Door Waste Incinerators

HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-08-07

Smallest Waste Incinerator for PPE waste face mask glove waste

Smallest Waste Incinerator for PPE waste face mask glove waste
Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney
ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications

Model

YD-10

Picture

 

Feed Capacity

Average 20 kgs per feeding

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

Ave. 4.2 Kgs/Hour

External Dimensions

Dia.100 x 130cm (mainbody)

Internal Dimensions

Dia.50 x 80cm

Waste combustion chamber

200Liters

Oil Tank Capacity

100 Liters

Door Opening

35 x 35cm

Chimney

1.5M

Gross Weight

Ave.400kgs

Chamber Material

Refractory Concrete&Ceramic Fiber 

Max. Heat Value

42,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

14000C

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-17

Clover's Social Media